How to Troubleshoot the New Inverter Compressor Refrigerators

Posted by Samurai Appliance Repair Man, in Refrigerator Repair 16 October 2013 · 3,009 views
refrigerator, inverter and 4 more...
The new inverter compressors ain't like the old skool compressors used in yo momma's beer cooler. Oh, they still do the same basic job-- pump refrigerant vapor. But you have to troubleshoot them differently from the old skool compressors. In their quest to comply with increasingly onerous Energy Star requirements, all the appliance manufacturers are producing refrigerator models that use inverter compressors. Like it or not, inverter compressors are here to stay. Many a fine tech has been befuddled by these new compressor systems but not you! For the Samurai shall reveal the truth unto thee, and the truth shall set thee free.

Conventional Old Skool Compressors

Before we talk about how these inverter compressors work and and how to troubleshoot them, let's quickly review the old skool compressors so it's fresh in our mind when we compare with how the inverter compressors work.

In the conventional compressor technology that's been around for decades, the compressor has a start winding to help kick things off and a main (or run) winding that keeps the compressor going after it's started. A start relay and sometimes a start capacitor are used to momentarily power the start winding and then take it out of the circuit once the compressor is up and running. The compressor runs off standard, single-phase, 60 Hz 120vac.

If the start relay fails, the compressor will sit there trying but failing to start and drawing locked rotor (LR) current. Where the normal operating current draw on a conventional compressor is somewhere between 1 and 2 amps, LR current could be somewhere north of 8 amps. All that current makes heat, lots of heat. As the compressor sits there straining to start, it starts boiling the oil and burning the varnish insulation on the motor windings. If this goes on for very long, the compressor will literally self destruct (internally) from all the heat.

To prevent this unhappy scenario, the engineers added an overload device that's used to kill power to the compressor if something goes wrong, like a bad start relay, open compressor start winding, bad internal bearing, or a seized piston inside the compressor that prevents it from starting correctly. The idea being that if the problem is just a bad start relay (very common), this can be repaired easily and inexpensively compared to replacing the entire compressor (or refrigerator).

If you were to measure the resistance of the start winding and the main (or run) winding, you would find that the start winding has a much higher resistance. This is because the start winding is made of thicker wire to handle the extra current flow through it that's needed to get the compressor piston going from a dead stop.

A common troubleshooting technique with these old skool compressors is to rig up a test cord and manually power the compressor to see if it'll run. More details on compressor test cords here: http://appliantology...e-a-compressor/

Once they're up and running, these old skool, compressors run at the same speed and move the same amount of refrigerant vapor per minute. In other words, their refrigerant capacity and motor RPM is constant the entire time it's running. They can't work "harder," just longer.

So, let's summarize the old skool compressors:
- has two windings, a start and a run winding, which are physically different windings and have different resistances; the start winding has higher resistance than the run winding
- runs off standard 120vac household power
- uses a start relay to initially power the start winding and then take it out of the circuit after the compressor is up and running
- can rig up a test cord to directly power the compressor
- are constant capacity and speed machines

Keep all this in mind as we now look at the new inverter compressors...

Inverter Compressor Systems

Although inverter compressors do the exact same thing as the old skool compressors-- pump refrigerant vapor-- and they physically move the vapor the same way-- through a vapor-compression cycle-- they are powered and controlled very differently.

For one thing, inverter compressors use a special three-phase voltage produced by a special control board called an inverter. Fuggetabout 120 VAC, 60 Hz line voltage. We're not in Kansas anymore, boys and girls! Both the amplitude (amount) and frequency of the input voltage will vary. Typical specs are 80 to 230 VAC with the frequency ranging anywhere from 57 to 104 Hz. The higher the frequency, the faster the inverter compressor will run.

So, inverter compressors, unlike their old skool forebearers, really can work harder. In fact, this is exactly why the manufacturers are using these inverter compressor systems; they can match how hard the compressor needs to work to the actual refrigeration work needed to keep the beer cold. By doing it this way, the compressor draws less power and the manufacturers can meet the Energy Star requirements.

Inverter compressors have three windings, not just two like the old skool units. All three windings should have the exact same resistance. If the resistances vary from each other by as much as a 1 ohm, the compressor will not run correctly. In fact, this is one of the ways of checking an inverter compressor: making sure that all three windings have the exact same resistance. Check the manufacturer's spec for what that exact resistance reading should be. This is different from the old skool compressors with just two windings and the start winding has a much higher resistance than the run winding.

Remember how a common troubleshooting trick with the old skool compressors is to power it directly with a test cord and see if it starts? Don't try that on these inverter compressors because you'll permanently break it. If you're a professional Appliantologist and you do this on a service call, you just bought your customer a new refrigerator!

Let's summarize the inverter compressors:
- have three windings, not just two; all three windings have the exact same resistance
- does not use a start relay/overload device
- runs off a special voltage produced by an inverter board; the voltage varies in both magnitude and frequency: the higher the frequency, the faster the compressor runs
- variable capacity, variable speed
- cannot directly power the compressor (well, you could but you'd regret it)

Troubleshooting Inverter Compressor Systems

If you're working on an inverter compressor system where the compressor isn't running, you can't power an inverter compressor directly to test it. But you can (and should!) check the resistances in all three windings to rule out an open winding. If the compressor windings check good, this is not diagnostically conclusive that the compressor itself is good. But if, OTOH, the winding resistances are imbalanced or one of them is open, this is diagnostically conclusive that the compressor is bad.

Okay, so let's say the compressor windings check good but it's not running. Now what?

Now you have to check the inverter board itself. There are two different tests you can do on the inverter board to see if it's good or not:

1. Check for good input voltages.

An Inverter board will have two different input voltages:
- 120 VAC main power supply
- 4 to 6 VDC control voltage from the main control board (or Muthaboard-- a completely separate circuit board in the refrigerator)

If you're missing one of these voltages, the inverter board can't run the compressor. You'll need to backtrack and find the missing voltage. Could be a bad wire harness connector, bad muthaboard, etc. BTW, make all voltage measurements with everything CONNECTED. Otherwise, you'll get different readings that could be misleading.

OTOH, if you're getting both of these input voltages to the inverter and the compressor isn't running (and you've already checked the compressor winding resistances), then you need to do this next test:

2. Check the current draw on the 120 VAC power supply.

- Disconnect the 120 VAC power supply from the inverter board.
- Connect your amp meter around one of the wires supplying 120 VAC to the inverter board (doesn't matter which one).
- Reconnect the 120 VAC power supply to the inverter board and watch your amp meter.

If the meter stays at 0 amps, the inverter board is toast-- it's not even trying to start the compressor.

If you see the current draw jump to say 4 amps (typical LR current in these inverter compressors) and then drop off, keep watching. Most inverter boards will repeatedly try to power up the compressor. On GE refrigerators, for example, the inverter will try to start the compressor 12 consecutive times. If the compressor fails to start, the inverter will timeout for 8 minutes and then try again. Other manufacturers may have different test schemes but the idea is the same: if the inverter is working properly, you'll see activity on your amp meter as the inverter tries to do its job.

In the video below, I demonstrate troubleshooting an inverter compressor system on a GE refrigerator. The only thing I didn't show in the video is checking the inverter board's current draw. (Kudos to Brother denrayr for posting this comment on the Youtube page for this video!)



Here's the replacement inverter board I used to fix this refrigerator: http://www.repaircli...5X11138/2443233


How to manually cycle the GE WR30X10093 icemaker

Posted by Samurai Appliance Repair Man, in Refrigerator Repair, Icemaker Repair 05 August 2013 · 3,032 views
GE, icemaker, test, harvest and 2 more...
A useful and handy diagnostic technique when working on an ice maker problem is to manually initiate a harvest cycle to see with the ice maker will or will not do. Here's how to manually cycle the GE WR30X10093 ice maker:


Power On Diagnostics
When the icemaker is first connected to power and if thermistor temperature is 50°F (10°C) or higher,
the control will perform a Power On test before entering the freeze cycle.
The test consists of the following:
• Turn on the motor until it reaches home the next time.
• Turn on the water valve for 1/2 second.
• Tum on the heater for 1/2 second.
• Verify that the feeler arm was in the "in" and then in the "out" position.
• Verify that the motor was not in the home position and then in the home position.
• Verify that the motor does not remain on after being turned off.
• Proceed to the freeze cycle.
Note:The power on test will only add 1/2 second of water, which will not overflow the mold with a normal fill,
but may cause a small cube when the refrigerator is first started.
If the temperature is below 50°F (10°C), the control will power up normally.
If in the home position, the control will enter the freeze cycle.
If the motor is not home, the control will enter the harvest cycle but bypass water fill to avoid overfilling the mold.

Service Diagnostics
During the first 15 seconds that power is first applied to the icemaker,
the Service Diagnostic Test mode may be entered.
The service mode is entered by pushing the feeler arm from the "out" position to the "in" position
and back again 3 times and only 3 times within 15 seconds.
Note: If the icemaker has already started a harvest cycle and the arm is moving,
it may be impossible to properly move the arm and enter the service mode without allowing it to reset and powering up again.
The service diagnostic mode consists of a harvest cycle followed by a water fill.
The harvest cycle is entered immediately, regardless of icemaker temperature or arm position.
While in the harvest cycle in the service mode, the heater will remain on for a minimum of 20 seconds.
The water fill cycle will initiate the first fill (5.1 seconds) without waiting for the mold to "prechill".
Only one water fill occurs during the service mode, whether the thermistor has reached 39.2°F (4°C) or not.
The icemaker will exit the service diagnostic test on its own and enter the normal freeze cycle.



If the ice maker won't do the manual harvest, replace it. Here's the replacement you need: http://www.repaircli...0X10093/1399596


Source: how do you cycle test the WR30X10093 icemaker


Installing the foamed-in-place refrigerator door gaskets used on some Whirlpool and Kitchenaid models: A War Story

Posted by Samurai Appliance Repair Man, in Refrigerator Repair 04 August 2013 · 1,188 views
refrigerator, gaskets and 4 more...
Brother Willie shares his battle-scarred experience with replacing these types of refrigerator door gaskets. To summarize in a word: DON'T. Or, if you must because you're a professional Appliantologist, make sure you charge a lot for the job.

Sounds like you have a FIP, (Foamed-In-Place), door liner. I've only had to replace a door gasket on a FIP door one time and probably will not every do it again.

You have to cut the old gasket in four places, (in the middle on each side), and carefully pull the gasket lip straight out from under the plastic liner, being careful not to pull up and break the liner away from the foam.

They you have to make sure the channel is clear of any remaining foam particles with a putty knife about 1/2" in all the way around.

Then the you have to get the new gasket installed, this was the nightmare part. Says to insert opposite diagonal corners first then other two diagonal corners. First two-no problem, third corner-no problem, forth corner - OHHH!!!!! What B!TCH!!!!! It was a real fight to get it to stretch out enough without tearing the gasket to get it over and under the lips of the liner.



But Brothers PDuff and JJ Surfer offer these consoling words of wisdom:

Concur with Brother Willie on the gasket replacement. Attempt only as a last resort. I think if you follow the instruction sheets on those they want you to remove the door to replace the gasket.

FIP gasket aren't that bad to do. The replacement gaskets have a had plastic edge that snaps into channel between liner and door panel. After removing the old gaskets I put silicone caulking where the new gasket will snap into the liner. Two problems with FIP door gasket replacement:
1. If you don't put adhesive the gasket tend to slide, especially on the hinge side where the door cams constantly slide up and down
2. The gaskets often come in too small and need to be stretched, I've done plenty that go on no problem and I have had a lot that seem about 1/4 too short.
Basically the original gaskets are better and should only be changed if there are significant tears, splits or missing magnets.



Source: Kitchenaid fridge. KBRC36FKS02. Sporadic temp problems


Reading wiring diagrams: How the Defrost Cycle works in a Danby refrigerator

Danby, defrost, circuit, diagram and 2 more...
Brother Reg elegantly steps us through the circuit diagram for this one.

When the Defrost cycle starts (Timer Motor pauses),
the Neutral goes through the Defrost Heater, Defrost Thermostat, and Thermal Fuse to Line.
Whenever the Defrost Thermostat "opens",
the Neutral still goes through the Defrost Heater, but now travels through the Timer Motor
and "seeks" the Line through the Compressor.(and Overload).
Motor resumes, but since the Motor is of a "high" resistance, the Heater hardly heats anymore,
until the Timer completes it's "Defrost timing", and then it switches the Neutral back to itself and to the Compressor.
If any of those parts aren't working, the Motor may not run at the specific time.


Posted Image



Source: Help Me Read This Wiring Diagram


Electrolux and Frigidaire Refrigerator Water Valve Diode in Harnesses by Model and Ice Maker Style

Posted by Samurai Appliance Repair Man, in Refrigerator Repair, Icemaker Repair 23 June 2013 · 1,090 views
Electroluc, Frigidaire and 6 more...

I noticed I never could seem to find them on the part breakdown, so I made a list. Here ya go!


Electrolux and Frigidaire Refrigerator Water Valve Diode in Harnesses by Model and Ice
Maker Style.

Refrigerator Style Ice Maker Type Part Number
Side X Side Crescent Cube 5303918287
French Door Finger Evaporator 242102101
French Door Flex Tray 242119101
On French Door models it doesn't matter if there is a crescent cube ice maker in the
freezer section or not, order the diode according to the style of the ice maker that's in
the fresh food section.

http://appliantology...guration-guide/



Source: VALVE ASSY HELP






Like - Plus - Connect - View

Facebook-icon50x50.png google-plus-icon-50x50.png YouTube-icon50x50.png

Find Parts & Diagrams Here

Looking for Appliance Parts? Enter your model number, part number, or even a part description and find it here. 365-day return policy on all parts purchased here, even electrical parts that have been installed!

Search My Blog

Latest Visitors

Random Album Image

LG Refrigerator Training

38 user(s) viewing

0 members, 37 guests, 0 anonymous users


Bing (1)


FAQs | Store | Memberships | Repair Videos | Academy | Newsletter | Beer Fund | Contact


Use the Appliantology Parts Finder to Get What You Need!
Enter a model number, part number, type of appliance, brand, or even a part description.
365-day return policy on all parts purchased here, even electrical parts that have been installed!

Your Sometimes-Lucid Host:
Samurai Appliance Repair Man
"If I can't help you fix your appliance and make you 100% satisfied, I will come to your home and slice open my belly,
spilling my steaming entrails onto your floor."

The Appliance Guru | AppliancePartsResource.com | Samurai's Blog

Real Time Analytics