Jump to content


Use this Search Box to Find Appliance Repair Help Now
Need help finding your model number?
365-day return policy on all parts purchased here, even electrical parts that have been installed!


FAQs | Store | Memberships | Repair Videos | Academy | Newsletter | Beer Fund | Contact


Welcome to Appliantology.org, the Web's Premiere Appliance Repair Resource for DIYers!

The world-famous Samurai Appliance Repair Forums


You can post a question and get repair help for FREE! Click here to get started.


Already a member of the Appliantology Academy? Just sign in with your username and password in the upper right-hand corner of the screen.

 


Sunlight Appliance

Member Since 13 Apr 2012
Offline Last Active Yesterday, 09:58 PM

Posts I've Made

In Topic: GE Arctica SxS FF door pops open when closing freezer door PSC23MGPABB

Yesterday, 09:56 PM

Ok, thank you Durham. If I don't post back, it all turned out well.

 

I will look into data loggers.


In Topic: GE Arctica SxS FF door pops open when closing freezer door PSC23MGPABB

Yesterday, 02:38 AM

Hi,

 

I returned to install the 3 new thermistors. The next day I returned again to measure the temperatures with the laser thermometer. Had -5F in the freezer and 41F in the FF compartment top shelf, and 36F middle shelf. Inside the crisper drawers it was even colder. At the same time the digital display was reading -6 and 34. The compressor was off at that moment.

 

There is no food in the unit at present because the home is a vacation rental and the last bunch of tenants have gone. Pulling the evaporator cover off revealed the evaporator was hardly frosted and the upper 1/3 of it was warmer (lasering 30F). However, the ice maker is making plenty of ice and, as long as the cover is on, the panels are lasering -5 or even colder.

 

What I'm concerned about is when the new tenants arrive and stuff the fridge with their own food, temps will rise inside and they will complain that their goods are thawing/going bad (like the last tenants did).

 

The FF door is sealing very tightly now that the last tenants have gone. All the hardware is in good condition too.

 

Thoughts?


In Topic: GE Arctica SxS FF door pops open when closing freezer door PSC23MGPABB

13 September 2014 - 08:53 PM

you have two thermistors out of tolerance... which ones? I think you are over thinking the temp issue.

 

Freezer and Fresh Food.

 

 

a bad thermistor can create those temp issues. If the compressor seems okay, you have no choice but to replace the failed thermistors. A quintessential rule in appliance repair is to fix the obvious problems first. You must replace those thermistors before you can proceed further.

 

OK. Cool. I will replace them and post back.


In Topic: GE Arctica SxS FF door pops open when closing freezer door PSC23MGPABB

13 September 2014 - 06:39 PM

What is laser therm temp of the upper 1/3?

 

27F

 

 

I am confused regarding your diagnosis. Is this the result after you replaced the sensors? If so, did you give it sufficient time with the evap cover in place? Is it a rush to judgment?

 

Haven't replaced the sensors yet. I don't want my client to throw money away if there is a sealed system leak. When I arrived I took the back cover off and saw this frost pattern. Lasered the frosted area at 0F and unfrosted area at 27F.

 

 

The list and suggestions regarding the door issue is lengthy and to say you doubt any of those could be the problem without at first checking them is interesting indeed. Another possible rush in judgment?

 

I have the tendency to rush. This is something I try to keep under control. But, I found and studied your list before going out on this call. I checked for these things already. I will recheck when I go back.


In Topic: GE Arctica SxS FF door pops open when closing freezer door PSC23MGPABB

13 September 2014 - 12:37 PM

Thank you.

 

Is evap fan running with sufficient power? Did you test rpms of fan at the board?

 

Yes.

 

 

First step in door closing problems, remove all food on shelf edges, and on door shelves. Door shelves may be hitting compartment shelves or food on shelves.

 

Not this.

 

 

For other door closing advice, see http://appliantology...em/#entry257756

 

I doubt it's any of these but I will check again. Do you think the frost pattern is any cause for alarm? 2/3 of the evaporator is frosted. Upper 1/3 will not frost in present condition.



FAQs | Store | Memberships | Repair Videos | Academy | Newsletter | Beer Fund | Contact


Use the Appliantology Parts Finder to Get What You Need!
Enter a model number, part number, type of appliance, brand, or even a part description.
365-day return policy on all parts purchased here, even electrical parts that have been installed!

Your Sometimes-Lucid Host:
Samurai Appliance Repair Man
"If I can't help you fix your appliance and make you 100% satisfied, I will come to your home and slice open my belly,
spilling my steaming entrails onto your floor."


The Appliance Guru | Master Samurai Tech