Jump to content
Click here to check out this guide

FAQs | Repair Videos | Academy | Newsletter | Contact


Appliance Repair Tech Tips

  • entries
    219
  • comments
    728
  • views
    112,721

Control Board Troubleshooting: Inputs, Outputs, and Algorithms


Son of Samurai

5,513 views

Many techs are intimidated when it comes to troubleshooting control boards. After all, we're talking about computers here -- computers that just so happen to run appliances. But as complicated as that may sound, control board troubleshooting really boils down to just three things: measuring your inputs, measuring your outputs, and understanding the board's algorithm.

Screen Shot 2020-08-02 at 12.16.06 AM.png

Let's start with inputs. Input just means anything, be it a power supply or some information, that the board receives from some other component. The simplest input, and the one present on every control board, is the one I've circled above -- that's just the board's line and neutral power supply. Like any electrical component, it needs both of those in order to work its magic.

Screen Shot 2020-08-02 at 12.17.32 AM.png

Here's a different kind of input. See all those thermistors and switches? The purpose of all of those components is to provide information to the board. The thermistors tell the board what temperature various parts of the compartments are, and the switches inform it of the state of the doors.

Inputs like this are vital for testing, since a single bad input can cause the board to make bad decisions. If an out of spec thermistor tells the board that the FF compartment is 70 degrees, then of course the board is going to run the compressor nonstop, even if this causes food in the refrigerator to freeze. That's not the board's fault -- it's just doing the best it can with the information it's given.

If you're paying attention, you'll notice something interesting. In order for the board to determine the temperature that a thermistor is sensing, it has to measure the voltage drop across that thermistor. And to do that, it needs to send voltage to the thermistor. That's right -- the board needs to issue an output to these thermistors and switches in order to receive an input from them. Speaking of outputs...

Screen Shot 2020-08-02 at 12.19.38 AM.png

Here's a classic example of labelled outputs on a control board harness connector. That 13V, 5V, and two DC grounds are all outputs that the board is supposed to supply.

Sometimes outputs aren't labelled on the schematic, and they'll be elsewhere in the service manual -- like so:

Screen_Shot_2020-08-02_at_12_20.28_AM_1.png

Now that we're familiar with inputs and outputs, we can start talking about the key element of board troubleshooting. You don't have to understand every little thing that's happening on that control board -- primarily, you just need to know the inputs it's supposed to receive and the outputs it's supposed to send out.

Is the board not sending the proper output to the compressor? Make sure that it's getting the correct inputs. That means confirming its power supply, making sure the thermistors are in spec, etc. This is a classic example of using knowledge of inputs and outputs to form a troubleshooting strategy.

Does this mean that if you determine a board is receiving the correct inputs, but not putting out the correct outputs, that the board has failed? Not necessarily. There's a third element you need to be aware of: the board's algorithm.

Don't be intimidated by that word. In a nutshell, all it means is "the way the board makes decisions". The algorithm is the logic that the board operates on. Sometimes, if the board does or does not receive a certain input, it might make certain decisions about an output that aren't initially obvious to the technician.

Screen Shot 2020-08-02 at 12.14.36 AM.png

This is a good example of that. If you can parse that Korenglish, it's basically just saying that if the board receives an input saying that the compressor is not operating correctly, it will stop issuing the output of the RPM signal. The engineers who made this board programmed its algorithm to make that particular decision in this particular circumstance.

Why is this important to know? Well, let's imagine you're working on this refrigerator. You see that the compressor isn't running, so you start checking the board's outputs. Would you look at that -- the board isn't sending out an RPM signal to the compressor! Is that your problem? Must be a bad board, right?

The only way to know that the issue actually lies with the compressor is to be aware of this board's algorithm. And that means doing your homework, prediagnosing, and reading the service manual.

It really doesn't have to be any more complicated than that -- identify the inputs and outputs, and study the board's algorithm using whatever service docs you have. Those are the key steps to effective control board troubleshooting.

Want to learn more wisdom like this that will enable you to troubleshoot like a pro? Check out our online, self-paced, cutting-edge appliance repair training over at the Master Samurai Tech Academy. Click here to enroll today and learn how to troubleshoot modern, computer-controlled appliances.

  • Like 8
  • Thanks 1

5 Comments


Recommended Comments

THANK YOU!!! THIS IS WHY AM THE NUMBER ONE SUPPORTER!!! YES I GAVE MYSELF THE TITLE AND I'M KEEPING IT! CLEAR CONCISE APPLICABLE KNOWLEDGE AT IT'S BEST THAT CAN BE APPLIED IN REAL TIME TO OUR DAILY CHALLENGES AS TECHNICIANS!!  YOU ARE THE BEST!!

 

  • Like 3
Link to comment

By controlling the rpm of the compressor , you can increase or, decrease the capacity (BtUH) of the compressor.  Example : take forced (fast) freeze for instance.  You want to max out the rpm of the compressor for maximum cooling. It is a way to make the unit become more energy efficient. So depending on the algorithm programmed in the control board ,it take's the RPM  input along with other inputs to speed up or slow down the compressor .

I install mini-split system that can have up to 4 heads with only one condenser. It controls the rpm of the compressor based on the call from the various thermostats. If only one zone (room) need's cooling the compressor runs in a reduced capacity otherwise, it would freeze up and slug liquid because the evaporator fans in the other units are not running. 

Link to comment
  • Team Samurai
Son of Samurai

Posted

17 hours ago, jcraig9218 said:

What is the RPM signal?

Good question!

Here's where you have to parse the Korenglish a little. Normally, an RPM signal is the term we use to refer to an input that goes from a motor to a control board. These are most commonly generated by Hall sensors, but there are other ways of producing these signals, too. An RPM feedback signal like this is how the control can monitor the speed of a motor.

However, the excerpt from the service manual that I used here isn't really talking about a feedback signal. For one thing, compressors can't produce feedback signals. And for another, the excerpt is talking about an output from the board to the compressor, not the other way around.

What they're most likely talking about here is the three-phase power supply from the inverter to the compressor. Why they call that an "RPM command signal" escapes me, but clearly whoever wrote that paragraph didn't have the firmest grasp of English.

This is yet another circumstance where having a functional understanding of how these appliances helps parse poorly-written documentation. We know that an RPM feedback line doesn't exist here, so instead of being thrown by the strange terminology, we can figure out what they're talking about based on our understanding of compressor configurations.

If you want to learn more about BLDC configurations, check out this other post I wrote. It covers RPM feedback lines, among other things: 

 

  • Like 2
  • Thanks 1
Link to comment
×
×
  • Create New...