Amana, KitchenAid, Maytag and Whirlpool 25’ SXS Refrigerators
Adaptive Defrost Control failure may cause mul ple complaints
Possible Issues:
- No Cool - compressor fails to come out of defrost and no cooling takes place insu cient Cooling or Intermi ent Cooling
- Evaporator completely iced over - no defrost
- Water Filter Indicator Lights :
- Won’t reset
- Red light (change lter) on new product
- No WFI indicator light at all
- Unit is perceived to be the cause of a t