******Message to the moderator: Please could you delete my other thread about the same subject ( title Defrost problem Inglis WPW10292244 refrigerator, posted june 21) . I'm unable to correct the title with the right model number*****
My Inglis refrigerator still have a defrost problem. Here's what I've done lately. Today I had to defrost manually with a air dryer the evaporator.
But before doing the defrost thing , I tested with the maintenance menu the thermostat circuit. The JAZZ board still returned me an O (open) circuit. I then probed it with an ohmmeter disconnected from the circuit and still frozen. The thermostat read was ok. It read 0 ohm. So its closed. I reconnected the thermostat to the circuit.
I probed the resistance of the heating element ( disconnected from the circuit) It read 33 ohm. So its not burn open or shorted if the resistance value is ok. So everything in this area looks fine.
I tested the voltage at the two disconected terminals of the heating element and I mesured nothing. So I started a manual defrost in the maintenance menu of the Jazz board. I took again a voltage reading. Around 15v was present at the terminal. So I plugged the terminals back....nothing seem to happen. So I back probed the terminal and it read 0v. I disconnected the terminals, still in forced defrost mode, and now I read 14v. I reconnected the terminal and nothing 0v. So everything seem to point in the direction of a defective JAZZ board. What you guys think?