Jump to content
Click here to check out our structured, online appliance repair training courses for rookies and experienced techs.

FAQs | Repair Videos | Academy | Newsletter | Podcast | Contact

Stay connected with us...

Subscribe to our YouTube channel for lots of appliance repair tips and help! Subscribe to our MST Radio podcast to learn secrets of the trade. Sign up for our free newsletter and keep up with all things Appliantology.

Search the Community

Showing results for tags 'relay'.



More search options

  • Search By Tags

    Type tags separated by commas.
  • Search By Author

Content Type


Forums

  • Appliantology Welcome Center
    • Kendo Masters Hall of Fame
    • Site Orientation
    • Announcements
  • DIYer Appliance Repair Forums
    • DIY Appliance Repair Help
    • Find a Local Tech
    • Appliance Haikus
  • Appliance Service Manual Requests
    • Appliance Service Manual Requests Forum
  • Professional Appliance Technician Forums
    • Appliance Repair Tech Forum
    • Professional Appliantologist Webinars Forum
    • Samurai's Appliance Repair Video Classroom
    • Samurai’s Appliance Puzzles
    • The Dojo

Blogs

  • Samurai Appliance Repair Man's Blog
  • kdog's Blog
  • Mrs. Samurai's Kitchen
  • DurhamAppliance's Blog
  • applianceman97's Blog
  • LI-NY Tech's Blog
  • tpoindexter's Blog
  • Smashycomman's Blog
  • acfixerdude's Blog
  • Tech notes
  • Eugene's blog about stores, fixing, life, and more!
  • Moostafa's Hookah Tent
  • Son of Samurai's Blog
  • Quick's Blog
  • Beyonddoubt's Blog

Categories

  • Appliance Repair Manual Stash Access File®
  • Appliance Repair Manual Pot Luck Supper

Find results in...

Find results that contain...


Date Created

  • Start

    End


Last Updated

  • Start

    End


Filter by number of...

Found 18 results

  1. Hello all, I have a Maytag RSD22A, compressor won't start. Resistance values ok on all 3 pins. Can I check the relay and compressor by connecting 110V directly to the start pin, or is there a better way?
  2. tired to bake at 350º the other night and had a broiled loaf after 15 minutes at most. about 10 years old Relay board? Replace the whole board or can one specific relay be pointed to and replaced (if the are OTS relays and not proprietary.)
  3. Hello everyone. My Kenmore refrigerator began to make clicking noises three weeks ago after a power outage. I have replaced the relay twice with new ones. Replaced the cold control because it was going bad. Replaced the defrost board. Refrigerator is still clicking every 3-4 minutes, lights inside dim. The model number is 106.51103.10. It is only four years old. Capacitor checks OK. The readings that I am getting from the compressor are from the two bottom prongs: (8.5) from the common to the other prongs. (3.0) and (5.7). What should I do next? Is the compressor a goner? Thank you.
  4. Hi guys, I need some help. The symptom is it won't start- I've looked through all the posts I could find. I think it's the motor, or the control board. I've taken apart the whole dryer. No codes. Tested the door switch, the belt switch. the thermal fuse is good. the motor windings seem low. The main was 2.1 ohms, start was 2.0 ohms. spins freely. The control board doesn't have any burns or anything that looks abnormal. I also tested the P1-3 and P1-4 leads and the resistance was in spec, so it says to replace the board. I really don't want to spend 300 bucks on a board if that's not the problem, or if I can just solder a new relay on the board. I can hear the relay click when I hold start in the diag mode. my question is: how do I check the control board, the motor relay, and the motor? Thanks in advance, Marc
  5. GE side by side 33 years old, TFF24RCB. Compressor stopped running, cycled and clicked, unplugged. Did some research, found both the relay and gaurdette are NLA, so I bought a Supco 410 hard start, and waited for my electrically savvy friend to have time to look at it.. Relay appeared to have failed, no engagement for start, so no start when run voltage present.Installed the hard start, compressor started right up and fridge cooled down "close" to spec, maybe 5F higher than expected from diagram. Problems are running too long, but does cycle, front face next to door seal is hot, about 125F. All accessible coils and air path brushed out and vacuumed prior to fix. Relay WR7X138 and Gaurdette WR8X44 are both NLA, but IC102 has been suggested as a replacement relay, no idea on Guardette replacement, but it sure looks like a common part. Hard start has C, M, S that goes to compressor, and two black wires that were connected with wire nuts to the 3 wires from the fridge harness. Originally the condenser fan connected to temp control out on one end and between compressor and gaurdette on other end. Not possible with 3n1 hardstart as the thermal overload is internal, but pretty sure it was or has been running. Thanks.
  6. I have a Kenmore Coldspot side by side fridge 106.54683300. It has stopped getting cold. I cleaned the condenser which was very dirty, having not been previously cleaned 12 years. The compressor was very warm to the touch. When I plugged it back in the compressor would go on for about 10-15 seconds then cut out. A few minutes later, it would repeat that cycle. I thought perhaps it was too hot, so I unplugged it and let it cool down. No luck. I pulled the relay start assembly, (2255198) and replaced it with the new generation one 2319792. Still, I am having the same issue, compressor comes on, then clicks off after about 10-15 seconds. Compressor is cool now (hasn't been run in a few hours), same issue. Could it be the capacitor? Any ideas? I don't like drinking my jack and coke with no ice. All of the fans are working. Thanks.
  7. michla

    relays

    I have an older Amana GUC gas/forced-air furnace that has an AP5522K relay. Would anybody know the difference of a AP5222K relay that seems to be much more available?
  8. Version

    125 downloads

    Viking Technical Bulletin: Replacement PM010129 Relay Models: DEDO200 DEDO205 DEDO270 DEDO275 DESO100 DESO105 DESO170 DESO175 VDSC305 VDSC307 VDSC365 VDSC367 VDSC485 VDSC487 VEDO205 VEDO276 VESO105 VESO176 PUB TC-0010A-SP AUGUST 2008 Replacement relay part link: Part number: AP5317437
  9. File Name: Viking Technical Bulletin: Replacement PM010129 Relay File Submitter: Samurai Appliance Repair Man File Submitted: 21 Jan 2014 File Category: Appliance Repair Manual Pot Luck Supper Viking Technical Bulletin: Replacement PM010129 Relay Models: DEDO200 DEDO205 DEDO270 DEDO275 DESO100 DESO105 DESO170 DESO175 VDSC305 VDSC307 VDSC365 VDSC367 VDSC485 VDSC487 VEDO205 VEDO276 VESO105 VESO176 PUB TC-0010A-SP AUGUST 2008 Replacement relay part link: Part number: AP5317437 Click here to download this file
  10. Samurai Appliance Repair Man

    Burned Refrigerator Compressor Start Relay

    From the album: Refrigerator Repair

    Buy the replacement start device here: http://www.repairclinic.com/PartDetail/Start-Device/8201786/1177466 Watch the video here:
  11. Samurai Appliance Repair Man

    Whirlpool Even Heat Dryer Motor And Heater Relay

    From the album: Dryer Repair

    These 24vdc relays are used on the Even Heat control boards in some Whirlpool dryer models and are interchangeable. Buy the replacement relay here: http://www.repairclinic.com/PartDetail/Relay/3405281/528722
  12. Version

    39 downloads

    Whirlpool Dryer Motor / Heater Relays wiring Used in the Even Heat models: http://www.repairclinic.com/PartDetail/Relay/3405281/528722
  13. File Name: Whirlpool Dryer Motor and Heater Relays Diagram File Submitter: RegUS_PatOff File Submitted: 21 May 2013 File Category: Appliance Repair Manual Pot Luck Supper Whirlpool Dryer Motor / Heater Relays wiring Used in the Even Heat models: http://www.repairclinic.com/PartDetail/Relay/3405281/528722 Click here to download this file
  14. Version

    135 downloads

    KLIXON 4TM Compressor OVERLOADS KLIXON PTC START RELAYS 8EA SUPCO HARD START RELAYS
  15. Version

    57 downloads

    Electrolux technical policy and explanation regarding the use of hard start kits in refrigerator compressors.
  16. File Name: Use of Hard Start Kits on Refrigerator Compressors - Electrolux Policy File Submitter: Samurai Appliance Repair Man File Submitted: 11 May 2013 File Category: Appliance Repair Manual Pot Luck Supper Electrolux technical policy and explanation regarding the use of hard start kits in refrigerator compressors. Click here to download this file
  17. File Name: KLIXON 4TM Compressor Overload and Start Relays Technical Bundle File Submitter: RegUS_PatOff File Submitted: 07 Feb 2013 File Category: Appliance Repair Manual Pot Luck Supper KLIXON 4TM Compressor OVERLOADS KLIXON PTC START RELAYS 8EA SUPCO HARD START RELAYS Click here to download this file
  18. Samurai Appliance Repair Man

    Main Board Failure On An LG Washer Control Board Rear View

    From the album: Washer Repair

    See this topic for more info ==> Buy LG washer parts with a 365-day return policy here ==> http://www.repairclinic.com/LG-Washing-Machine-Parts
×
×
  • Create New...