Jump to content
Click here to check out this guide

FAQs | Repair Videos | Academy | Newsletter | Contact


Search the Community

Showing results for tags 'Upper limit'.

  • Search By Tags

    Type tags separated by commas.
  • Search By Author

Content Type


Forums

  • Appliantology Welcome Center
    • Site Orientation
    • Announcements
  • Professional Appliance Technician Forums
    • Appliance Repair Tech Forum
    • Master Samurai Tech Workshops
    • Samurai's Appliance Repair Video Classroom
    • Samurai’s Appliance Puzzles
    • The Dojo
  • Appliance Service Manual Requests
    • Appliance Service Manual Requests Forum
  • Appliance Repair Trade Resources
    • Looking for a Tech
    • Looking for a Job
    • Appliance Repair B2B Resources
  • DIYer Appliance Repair Forums
    • DIY Appliance Repair Help
    • Appliance Haikus

Blogs

  • Samurai Appliance Repair Man's Blog
  • kdog's Blog
  • Mrs. Samurai's Kitchen
  • DurhamAppliance's Blog
  • applianceman97's Blog
  • LI-NY Tech's Blog
  • tpoindexter's Blog
  • Eugene's blog about stores, fixing, life, and more!
  • Appliance Repair Tech Tips
  • Koi Guy's Amazing Compendium of Timeless Appliantological Wisdom
  • Rhubarb Tau's Sloggy Vlog Blog Bog

Categories

  • Appliance Repair Manual Stash Access File®
  • Appliance Repair Manual Pot Luck Supper

Find results in...

Find results that contain...


Date Created

  • Start

    End


Last Updated

  • Start

    End


Filter by number of...

Found 1 result

  1. Hi, I have an older Bryant 75000 BTU Natural Gas furnace built in 1986 with a HH84AA 011 board. The thing started acting up where after the furnace would cycle the blower would come on briefly for a couple of seconds then turn off about 3 times within about 10 seconds. This had gone on for about a month. Now the blower will not turn off at all. We have to turn the power off to the furnace to get it to shut down. When it gets cold in the house we flip the switch and after the flame goes out and HX cools we flip the switch again. I’ve searched the forum and found a few instances where the blower stays on for this type of system. Here is what I’ve learned and done so far… I was looking for a bad Transformer which is working and putting out 24V. Checked for power between SEC 1 and SEC2 and get 24v. Checked the voltage between R and C and I get 24 volts as well so the board seems good. I cleaned the contacts on the relay and getting a spark when switched on. Checked the upper limit and it seems to be working fine along with the fuse on it is OK too. I disconnected the T-stat wires and tested everything again and everything seems fine. BUT the blower still will not turn off! I started tracing looking for any bare, worn or broken wires or loose connections and everything seems fine as well. I thought I'd have this fixed by now with the info I found on this site (you guys give great info) But this thing is driving me nuts! ANY HELP would be appreciated! Thanks! Jim J
×
×
  • Create New...