I have a VT-155SBB that’s acting up. On first plug in the unit works well and cools down to it’s lowest setting of 40℉ without issue. However, after that first cycle the compressor attempts to kick back on but fails to fully start and stalls. After several seconds of being stalled the overload protector trips cutting the power. This cycle continues until I unplug the unit and let it sit for several minutes (~15 minimum). For the sake of fully diagnosing the problem I replaced the overload protector, the start relay, and the capacitor, but the faulty functioning continues after the first cooling cycle. It seems that the compressor won’t start back up after the first cycle when there is still head pressure in the system to overcome. I checked the resistance of the common to start terminals at 8.4 ohms, common to run at 6.0 ohms, and start to run at 12.4 ohms. All of the terminals read infinite to ground. Is the compressor motor start winding bad or is more diagnosis required? Refrigerator P/N: VT-155SBB Compressor P/N: NB1116HY
-
GE Profile Side-by-side Loud Bang / Backfire Sound
John R posted a topic in DIY Appliance Repair Help
Hi, I have a 15 year old GE Profile Side-by-side that makes a very loud bang / backfire sound when the compressor shuts off. It seems to cool ok, but the noise is very loud and can't be good. I have read about cleaning out dust and build-up, and attempted that, but so far that has not worked for me. I don't know if I need to clean out the fridge, angle it back and get at it from underneath. Any suggestions? Thanks - John