Hi,
I need tour help. I have a whirlpool wrx988sibm01 four door refrigerator. None of fhe compartments are cooling. Compressor isn't coming on.
I checked the compressor (VEGZ 7H) it checks out good. Equal 6.8ohm across all windings/ terminals. No continuity to ground for any of the terminals.
All fans appear to work. As soon as i turn on power
First, icemaker fan comes ON, then condensor fan comes ON, then after a while the icemaker fan goes OFF and top compartment fan comes ON. Then after a while the freezer evaporator fan comes ON. Once the condensor fan turns ON, it stays ON. But the compressor never comes ON.
Then i checked the inverter (W10154805; VCC3 1156 19 A 52):
It is receiving 110v. The control voltage reads 7.14vdc, is it too high. Your video spoke of 4-6vdc for control voltage.
I also checked the output voltage from the inverter. 3 being the bottom terminal in the upside down triangular configuration of terminals and G being ground. (inverter should be putting out 230v 53-153hz), can't tell if this is ac vs. dc and how to measure for this 230v reading, i.e. across which terminals etc. So measure what i could and here are my readings:
G-1 = 167vdc; G-2 = 154vdc; G-3 = 154vdc
1-2 = 317vdc; 1-3 = 317vdc; 2-3 = 0vdc
I looked for current draw on one of the 110v wire coming to inverter, it never went past 0.03Amps, consistent with the low power fans that came ON, but never the compressor.
Now, i am at my wits end, with no path to troubleshoot the issue. Can someone please help.
Thanks in advance to anyone willing and able to help me.