SUBJECT: Air leaking into the Ice Room from a gap between the wall and the ice room floor. (Direct Contact Ice Makers only)

Symptom: Frozen water on ice room floor, ice on bottom of ice maker, water dripping into the fresh food section.

Models:

RF23HCEDBBC/AA RF28HFEDTBC/AA RF28HFEDTSR/AA RF28HFEDTWW/AA RF28HFPDBSR/AA RF30HBEDBSR/AA RF30HDEDTSR/AA RF31FMEDBBC/AA RF31FMEDBSR/AA RF31FMEDBWW/AA RF31FMESBSR/AA RF323TEDBBC/AA RF323TEDBSR/AA RF323TEDBWW/AA RF32FMQDBSR/AA RF32FMQDBXW/AA RF34H9950S4/AA

RF34H9960S4/AA RF23HCEDBSR/AA RF23HCEDBWW/AA RF24FSEDBSR/AA RF263BEAEBC/AA RF263BEAESP/AA RF263BEAESR/AA RF263BEAEWW/AA RF263TEAEBC/AA RF263TEAESP/AA RF263TEAESR/AA RF263TEAEWW/AA RF28HDEDBSR/AA RF28HDEDTSR/AA RF28HFEDBBC/AA RF28HFEDBSR/AA RF28HFEDBWW/AA

PUB ASC20140818002


User Feedback

Recommended Comments

ApplianceTechTn.com

Posted

This is a old Service Bulletin outdated  newest has replace Main pcb too. 

philcheck

Posted

DO WE HAVE THE LATEST BULLETIN?

brm

Posted

OK THIS IS OLD PLEASE DIRECT ME TO THE NEW ONE FOR MOD: RF32FMQDBSR

Krobjr1

Posted

On 12/10/2019 at 7:26 PM, ApplianceTechTn.com said:

This is a old Service Bulletin outdated  newest has replace Main pcb too. 

Service bulletin number is ASC20170602002

Patrick.j

Posted

Thanks 

  • Like 1
MatthewF

Posted

Thanks guys! 

×
×