Jump to content
Click here to check out this guide.

FAQs | Repair Videos | Academy | Newsletter | Contact


Search the Community

Showing results for tags 'conditioner'.

  • Search By Tags

    Type tags separated by commas.
  • Search By Author

Content Type


Forums

  • Appliantology Welcome Center
    • Site Orientation
    • Announcements
  • Professional Appliance Technician Forums
    • Appliance Repair Tech Forum
    • Master Samurai Tech Workshops
    • Samurai's Appliance Repair Video Classroom
    • Samurai’s Appliance Puzzles
    • The Dojo
  • Appliance Service Manual Requests
    • Appliance Service Manual Requests Forum
  • Appliance Repair Trade Resources
    • Looking for a Tech
    • Looking for a Job
    • Appliance Repair B2B Resources
  • DIYer Appliance Repair Forums
    • DIY Appliance Repair Help
    • Appliance Haikus

Blogs

  • Samurai Appliance Repair Man's Blog
  • kdog's Blog
  • Mrs. Samurai's Kitchen
  • DurhamAppliance's Blog
  • applianceman97's Blog
  • LI-NY Tech's Blog
  • tpoindexter's Blog
  • Eugene's blog about stores, fixing, life, and more!
  • Appliance Repair Tech Tips
  • Koi Guy's Amazing Compendium of Timeless Appliantological Wisdom
  • Rhubarb Tau's Sloggy Vlog Blog Bog

Categories

  • Appliance Repair Manual Stash Access File®
  • Appliance Repair Manual Pot Luck Supper

Find results in...

Find results that contain...


Date Created

  • Start

    End


Last Updated

  • Start

    End


Filter by number of...

Found 1 result

  1. Whirlpool thru-wall A/C, 10000-12000 BTU range. 220v unit running in a small condo unit. Set up to cool living room and kitchen, not sure of sq footage but these rooms are small. The unit initially cools but compressor cuts out within 15 minutes and usually doesnt come back. Makes a smell described as "musty". I measured 206v at the outlet, changes less than 1/2 volt with load (compressor on/off). I assume this means that the condo building is supplied with 3-phase power. Unit draws ~3.25A with compressor on. It didnt cut out while I was there, maybe a hot day makes a difference. This unit has been replaced twice, so cant be manufacturing defect. There are no obstructions on the exhaust as far as I can tell. It is on the sunny south-facing side of the condo but I cant imagine that makes a difference. My hunch is that these units cant tolerate 208v power supplied by 3-phase service, and the compressor is overheating. So easiest solution is to install a 110v unit, rewiring the outlet? Any ideas appreciated. TIA, Charley
×
×
  • Create New...