Jump to content
Click here to check out our structured, online appliance repair training courses for rookies and experienced techs.

FAQs | Repair Videos | Academy | Newsletter | Contact


Samurai Appliance Repair Man's Blog

  • entries
    861
  • comments
    1,408
  • views
    3,311,659

7 Comments


Recommended Comments

applianceman1

Posted

Love these pop quizzes.

  • Team Samurai
Samurai Appliance Repair Man

Posted

Glad you like 'em, Walter.  What's the answer? :)

Patricio

Posted

Both compartments warm, I  be checking  if compressor is a running along wit da fan hoss  Obvious no cooling taka place wid out comp doing it job

  • Team Samurai
Samurai Appliance Repair Man

Posted

Both compartments warm and condenser fan running-- compressor would be my next stop!

AQAppliances

Posted

I would check the freezer wall first and foremost. Check for possible defrost problem or fan issue. No way I am starting by pulling the refrigerator out and checking the condenser fan motor.

  • Team Samurai
Samurai Appliance Repair Man

Posted

On February 28, 2016 at 6:56 PM, AQAppliances said:

I would check the freezer wall first and foremost.

The flow chart starts with both compartments warm. Even in a defrost failure, the freezer would be "cold"-- not necessarily 0F, but still cold. 

At this point, you know there's a problem with the sealed system-- either compressor not running or refrigerant leak. Why waste time tearing apart the freezer? 

 

Rich Armstrong

Posted

I thought the answer would be: While your are already looking for a functioning condenser fan why not break out the IR gun and get the the temperature split at the middle of the condenser and room temperature. We are looking for a difference of at least 20*. If not there is a failure in the compressor or a Freon leak!

  • Like 1
×
×